The P630
generates sufficient power with the internal power amplifier
to energize all defects from air-gap problems, puffing
sounds, loose particles, constrained voice coil, cabinet
rattling, litze wire clatter, glue problems etc., which
generally speaking are known as Rub & Buzz distortion.
P630 are able to measure microphone
frequency response due to the built-in output compress
function. This enables a constant signal pressure even from
a standard loudspeaker.
Note picture show old B&K input plugs. Standard input plugs
are of Lemo type.
|
The system consists of a service friendly 19" P600
cabinet with standard sized modules plus a PCI card with 4 x 24 bit
A/D & D/A converters and a PCI I/O card to control the cabinet.
The cabinet contains protected 15 volt rms. power amplifier
(optional 20 volt rms.) , up to 6 different input modules, an I/O
module and microphone power supply.
On request it is possible to install a
digital power amplifier with a output of max 48 V rms, 600 VA,
30 A peak.
The software is arranged in four modes, an operator mode, a
technician mode, a global set-up mode, and a utility mode, which all
are protected by passwords.
|
The operator mode is for
day-to-day production testing of parameters alfaready set-up
in the technician mode. This mode is specially designed for
non skilled personnel or for fully automated operations.
|
|
In the technician mode all
parameters as frequency range, test level, reference curves
limits, Rub & Buzz and THD filters etc. are customized to
the specific requirements for each individual test.
|
|
In the global
set-up the graphical presentation, test control, paths for
files, chain of tests, statistics etc. are defined in the global
set-up the graphical presentation, test control, paths for
files, chain of tests, statistics etc. are defined.
|
|
For
post-processing and manipulation of stored data there are a
number of Utility functions as Export and Import of data,
Statistical analysis and graphical display of batch data
etc. The statistical analysis including calculation of
various numbers of standard deviation and average curves to
determine the test limits. The analysis is able to find a
best matched measured unit against the average or another
unit.
|
The P630 is as standard equipped with two inputs. There are as
standard four analyzing channels, one for frequency response, one
for impedance and two for distortion / Rub & Buzz. Extra inputs (up
to six) can be added to the system.
All necessary hardware, cables and software etc. are included in
a standard delivery except for suitable microphones and PC.
List of common P630 test parameters:
Frequency response against upper / lower limits
|
Sensitivity against upper / lower limits with move option
|
Impedance against upper / lower limits
|
Frequency response against 2. upper / 2. lower limits
|
Sensitivity test point 1
|
Resonance
/td>
|
Frequency response against 3. upper / 3. lower limits |
Sensitivity test point 2 |
Qms |
Average of Frequency |
Sensitivity test point 3 |
Qts |
Average of Frequency in groups |
Sensitivity test point 4 |
F (Fres./Q) |
Average1 of sensitivity point 1-5 |
Sensitivity test point 5 |
Re |
Average2 of sensitivity point 1-5 |
Rub & Buzz channel B against upper / lower limits |
Voice Coil offset, BL |
Polarity |
Rub & Buzz channel D against upper / lower limits |
EBP |
Slope of frequency |
THD |
T/S parameters |
Current Distortion |
Ambient Noise Control |
Cpk / Ppk |
BL-test |
Hi-2 test |
2. Resonance test |
P630pro version 1.4 Ai-Mode added
New Functions have has added from version 1.3t
Second resonance test added. R-test can test for a minimum ar a
maximum.
New Functions have has added from version 1.3s
Hi-2 test added
New Functions have has added from version 1.3m
A new extended dat file
format added to save more information regarding measured data
New Functions have has added from version 1.3k
Number of max. test points changed from 250 to 500 points.
Graph Invert function added.
Selection of font size added to main menu.
Graph curve thiknes function added. Normal / bold.
New Functions have has added from version 1.3j
Slope test added
New Functions have has added from version 1.3i
P630 now run on Searph 8, and PEX-D24 boards.
Multi dongel key support. This version of P630 progam run on all
registrated dongles with a valid P630 serialnumber.
Run on 32 bit systems as well on 64 bit.
Supported cards for 32 bit: Marc4d (asio only), Marc4m, Trace 8, Seraph
8, PIO-D24 and PEX-D24.
Supported cards for 64 bit: Trace 8, Seraph 8, PIO-D24 and PEX-D24.
See
Card/Sw table
New Functions have has added from version 1.3- to 1.3-h
P630 now run on Trace 8 board.
New Functions have has added from version 1.3-c to 1.3-e
Start frequency of sweep changed from 20 Hz to 5 Hz as
minium.
New Functions have has added from version 1.3 to 1.3-c
A Bl test has been added to test for asymmetry distortion in
impedance to detect coil offset.
A Cpk / Ppk curve analyze has been added.
A Curve Editor in a table form has been added.
A Jitter function has been added.
A Curve Display Selector have been added to give a better curve
presentation.
New Functions have has added from version 1.2g to 1.3
Windows Vista supported.
New Functions have has added from version 1.1a to 1.2g
P630 now run on Marc4-d & Marc4-m boards.
Reset menu in edit mode have added a reset for each channel primary
and secondary.
A pure phase test has been added as a secondary test.
Separate THD measurement has been added as secondary test to enable
2 different Rub & Buzz measurement at same time.
EBP measurement and test added in impedance measurement.
Measurement of Re added in impedance measurement to support Q & EBP
functions.
Ambient Noise Check control has been added for better reliability.
A hardware configuration menu has been added to better add and
modify hardware.
A hardware calibrations menu has been added to enable user to file
calibrate and check hardware.
Thiele Small parameters added.
New Functions have has added from version 1.0 to 1.1
5 - separate sensitivity test points added.
2 - average test for the 5 sensitivity points. Filter added for
channel C to enable Current distortion test in speakers - the
I-test. Support external power amplifier this together with a
optional external box to enable impendence measurement in single or
multiplexed mode.
|